대학교 대형강의실의 조명조건별 조명환경평가
Evaluation on the Lighting Environment of the Univeristy Assembly Hall
- 충북대학교 생활과학연구소
- 생활과학연구논총
- 생활과학연구논총 제7권 1호
-
2003.0763 - 77 (15 pages)
- 76
The purposes of this study are to evaluate the lighting environment of a university assembly hall and to make clear the problems of conditions of lighting operation. The field measurement on the illumination level and the questionnaire survey on subject response of the lighting environment with students were carried out at an assembly hall in C university, Cheongju. These survey were taken on 4th and 9th of December, 2002. The illumination levels of the assembly hall in the condition A (157~403 lux) were lower than standard (400 lux). The illumination levels of the condition B (16~372 lux) and condition C (0~1 lux) were poor. The illumination levels of the condition D (231lux) were somewhat lower than standard. It was found that the present condition of the lighting environment of the university assembly hall is inappropriate illumination level and uniformity for lecture.
Abstract
I. 서론
II. 문헌고찰
III. 연구방법
IV. 조사결과 및 논의
V. 결론 및 제언
참고문헌
(0)
(0)