익상견갑의 평가를 위한 "Scapulometer" 의 신뢰도 연구
Reliability of Scapular Winging Measurement Using a Scapulometer
- 한국전문물리치료학회
- 한국전문물리치료학회지
- 한국전문물리치료학회지 제17권 제2호
-
2010.0510 - 16 (7 pages)
- 157
This study was undertaken to develop the scapulometer, a measuring tool for scapular winging, and to determine the reliability of scapulometer. Thirty subjects with scapular winging greater than 2 em participated in this study. Two examiners measured scapular winging using the scapulometer. Standardized measurement position of each subject was as follows: neutral position of shoulder and wrist, 90도 flexion of elbow, and cuff weight of 5% and 10% of body weight (BW) to neutral wrist. The interrater and intrarater reliability were calculated with an intraclass correlation coefficient (ICC) with 95% confidence interval(CI) and standard error of measurement (SEM) at 5% BW and 10% BW. The level of scapular winging was tested between 5% BW and 10% BW with a paired t-test. The interrater reliability was shown to be high at 5% BW (ICC(2,k)=.955, 95% CI=.900~.979,SEM=.07) and at 10% BW (ICC(2,k)=.968, 95% CI=.930~.985,SEM=.06). The intrarater reliability was shown to be high at 5% BW (ICC(2,k)=.921, 95% CI=.842~.961,SEM=.09) and at 10% BW(ICC(2,k)=.906,95% CI=.813~.954,SEM=.10). The level of scapular winging was significantly different between 5% BW and 10% BW. Conclusively, it is demonstrated that the scapulometer is an objective and qualitative measurement tool for scapular winging.