줄자를 이용한 하지부피 측정시 부위별 검사자간, 검사자내 신뢰도 측정
Intertester and Intratester Reliability of Tape Measurement on Lower Extremities
- 한국전문물리치료학회
- 한국전문물리치료학회지
- 한국전문물리치료학회지 제7권 제1호
-
2000.0338 - 45 (8 pages)
- 38
Tape measurement for evaluating edema is frequently used by clinicians. The primary purpose of this study is to determine the intertester and intratester reliability of tape measurement carried out by two physical therapists on lower extremities. The intertester and intratester reliability of six anatomical landmarks measurements were determined in six healthy subjects. The measurements were taken in five sessions by each tester. The intraclass correlation coefficients (2,1) were between .87 and .99 for intertester reliability. Intratester reliability was .93 and .99 for A tester and .82 and .99 for B tester. The average range of variation was .13 to .54 in six landmarks. The reliability of six volume measurements was very high. These results support the use tape measurement as a reliable tool for measuring limb girth.