전방깊이에 대한 수정체 두께의 비율이 ICL 삽입 후 Vault에 미치는 영향
The Effect of Lens Thickness to Anterior Chamber Depth on the Vault after ICL Implantation
- 대한안과학회
- 대한안과학회지
- Ophthalmological Society,volume53,number8
-
2012.081081 - 1087 (7 pages)
- 3
Purpose: To evaluate the crystalline lens thickness/anterior chamber depth (CLT/ACD) ratio as a preoperative factor that affects the vault after implantable contact lens (ICL) implantation. Methods: A total of 130 eyes of 130 patients who received bilateral ICL implantation were included in the present study. The preoperative CLT/ACD ratio was analyzed to determine if the patients had any correlation with postoperative vault by Visante optical coherence tomography (OCT). Results: The mean vault was 0.58 mm ± 0.23 at postoperative 2 months. Eight eyes (6.15%) had low vault, 93 eyes (71.53%) had ideal vault and 29 eyes (29.31%) had high vault. The CLT/ACD ratios were 1.04 mm ± 0.11, 0.96 mm ± 0.09 and 0.90 mm ± 0.09 in the low vault group, ideal vault group and high vault group, respectively (p < 0.01). The CLT/ACD ratio showed statistically significant correlations with postoperative vault in univariate analysis (r = -0.4718; p < 0.01) and in multivariate analysis (p < 0.01). Conclusions: Vaults after ICL implantation have a negative correlation with the preoperative CLT/ACD ratio. The results from the present study may improve the prediction of postoperative vault after ICL implantation. J Korean Ophthalmol Soc 2012;53(8):1081-1087
(0)
(0)