피기백 인공수정체를 이용한 백내장 수술 후의 잔존 굴절 이상의 교정 1예

A Case of Corrected Residual Refractive Error after Cataract Surgery with the Sulcoflex Piggyback IOL

  • 3
121510.jpg

Purpose: To report a case of corrected residual refractive error after cataract surgery with sulcoflex piggyback intraouclar lens (IOL). Case summary: A 77-year-old man was diagnosed as having hypermature cataract in the right eye and his corrected visual acuity in the same eye was hand-motion before surgery. Refractive error was +9.0 diopter (D) 6 months after conventional cataract surgery in the right eye. The authors performed additional cataract surgery using a piggyback method inserting a +10.0 D IOL in the ciliary sulcus. Four weeks after surgery, his refractive error was -1.25 D, visual acuity increased to 120/200 and 60/200 (with and without correction, respectively). No complication was observed during follow-up time and the patient was satisfied with his results. Conclusions: Correction of residual refractive error after cataract surgery with sulcoflex piggyback IOL is safe and effective. J Korean Ophthalmol Soc 2014;55(12):1890-1894