577 nm 레이저 섬유주성형술의 단기 임상효과
Short-Term Clinical Outcomes of Laser Trabeculoplasty Using a 577-nm Wavelength Laser
- 대한안과학회
- 대한안과학회지
- Ophthalmological Society,volume55,number4
-
2014.04563 - 569 (7 pages)
- 4
Purpose: To evaluate the pressure-lowering effects of single-spot laser trabeculoplasty and patterned laser trabeculoplasty using a 577-nm wavelength laser. Methods: A total 35 eyes of 35 patients with primary open-angle glaucoma were enrolled in this study. Eighteen eyes of 18 patients were treated with 360° single-spot laser trabeculoplasty and 17 eyes of 17 patients were treated with 360° patterned laser trabeculoplasty. All patients were evaluated after laser trabeculoplasty at 1 week, 1 month, 3 months, and 6 months using slit lamp examination and Goldmann applanation tonometry. Results: At 6 months postoperatively, the single-spot laser trabeculoplasty group had a mean IOP of 15.89 ± 3.89 mm Hg with a mean IOP reduction of 37.1%, while the patterned laser trabeculoplasty group had a mean IOP of 17.57 ± 2.64 mm Hg with a mean IOP reduction of 27.1%. Conclusions: Laser trabeculoplasty with a 577-nm optically pumped semiconductor laser was safe and demonstrated an IOP lowering effect. There were no significant differences in the IOP lowering effects between the single-spot laser trabeculoplasty and the patterned laser trabeculoplasty. J Korean Ophthalmol Soc 2014;55(4):563-569