상세검색
최근 검색어 전체 삭제
다국어입력
즐겨찾기0
학술저널

하악지 시상절단술시 견고 고정 나사의 골편간/골내 길이 및 비율에 대한 연구

A STUDY ON BONE-CONTACT TO INTER-SEGMENTAL LENGTH RATIO OF RIGID FIXATION SCREWS USED IN BSSRO FOR MANDIBULAR SETBACK

  • 0
127097.jpg

Objective: To evaluate the ratio between bone-contact length and inter-segmental length of the rigid fixation screw used in bilateral sagittal split ramus osteotomy (BSSRO) for mandibular setback. Material and Methods: Records of 40 patients with Class III malocclusion were selected. 20 of them had BSSRO, while the other 20 had BSSRO with maxillary LeFort I osteotomy. All of the patients had three noncompressive bicortical screws inserted at the gonial angle through transcutaneous approach. Two screws were inserted antero-posteriorly above inferior alveolar nerve and one screw was inserted below. The lengths of bone-contact and that of inter-segmental part were measured using cone-beam computed tomography. Ratio between these two measured lengths was calculated. Results: Both bone-contact and inter-segmental lengths were longer in BSSRO group than in BSSRO with maxillary LeFort I osteotomy group. Ratio of bone-contact to inter-segmental length was lower in BSSRO group than in BSSRO with Lefort I group. Both bone-contact and inter-segmental lengths were longer at the antero-superior position than at the inferior position. However, their ratio showed little difference. Conclusion: This study suggest that stability of screws in BSSRO group was greater than in BSSRO with Lefort I group. Stability of screws at the antero-superior position was greater than at the inferior position. Ratio of bone-contact to inter- segmental lengths was 0.2 in average.

(0)

(0)

로딩중