Mini-implant를 이용한 하악골 우각부 골절의 효과적인 정복;
EFFECTIVE REDUCTION OF MANDIBULAR ANGLE FRACTURE WITH MINI-IMPLANT; CASE REPORT
- 대한구강악안면외과학회
- 대한구강악안면외과학회지
- 대한구강악안면외과학회지 제33권 제4호
-
2007.08397 - 400 (4 pages)
- 4

In an open reduction of the mandibular angle fracture, it is crucial to approximate each fracture segment as closer as possible for the reduction of the healing period. In this case report, we proposed a new technique for the mandibular angle fracture. This was designed to minimize the gap between two separated segments using mini-implants and surgical wires. Mini-implants were placed around the fracture line, followed by wire ligation to minimize the fracture gap. And then internal fixation was easily employed with plates and screws. The advantages of this technique were reduced time for operation, the promotion of healing, rapid functional recovery, and few complications.