학술저널
Life-threatening airway obstruction after flapless implant placement in the anterior mandible
Life-threatening airway obstruction after flapless implant placement in the anterior mandible
- 대한구강악안면외과학회
- 대한구강악안면외과학회지
- 대한구강악안면외과학회지 제38권 제5호
-
2012.10310 - 313 (4 pages)
- 5

This paper reports a patient who had an airway obstruction caused by a hemorrhage of the mouth floor that occurred after she underwent flapless implantation in the region of the mandibular anterior teeth. The hemorrhage may have been caused by iatrogenic malpositioned fixture and patient’s hypertension. The lingual periosteum was not dissected during the flapless procedure. Therefore, when hemorrhage occurred, the blood did not drain easily into the oral cavity but instead drained into the deep neck region, which might have been the cause of the airway obstruction.
I. Introduction
II. Case Report
III. Discussion
(0)