Ventilation rates can be measured directly by a tracer decay method, although little is known of the effects of different sampling intervals on decay rte calculations. This study determined variations in decay rates calculated by three techniques using residential ozone decay data. The calculation techniques were a regression technique, decay techniques using half-life and average-life, and finite difference techniques using two different time intervals. Variation associated with regression technique calculations for residential ozone decay rates based on data from both sample intervals were within 10% (2.81±1.88 hr-1). However, both half-life and finite difference technique calculations using a shorter-time interval were significantly different from those obtained with the regression technique(p<0.05). Therefore, the use of short sampling intervals in tracer decay may cause significant error in decay rate calculations.