원형 pin fin과 반원형 pin fin 사이의 성능 비교
Comparison of Performance Between a Circular Pin Fin and a Half Circular Pin Fin
- 강원대학교 산업기술연구소
- 산업기술연구
- vol.36
-
2016.0917 - 22 (6 pages)
- 65
A circular pin fin(CPF) and a half circular pin fin(HCPF) are by using the one-dimensional analytic method. For these two fins, 90% of the maximum heat loss, Corresponding fin length for 90% of the maximum heat loss, fin effectiveness and fin efficiency are compared as functions of convection characteristic number and fin radius. Also, the ratio of heat loss from the HCPF to that from CPF listed with variation of fin length when the fin volumes are the same. One of the results shows that the efficiency of a CPF is larger than that of a HCPF while the effectiveness of a CPF is smaller than that of a HCPF when convection characteristic number, fin length and fin radius are the same.
1. 서론
2. 1차원 해석적 방법
3. 결과 및 고찰