상세검색
최근 검색어 전체 삭제
다국어입력
즐겨찾기0
학술저널

소형 소각로에서 운전조건과 온도분포 사이의 관계 분석

Analysis of the relationship between operational condition and temperature distribution in a small incinerator

  • 4
138393.jpg

One aims to find out how the operation condition of secondary inlet angle effects the temperature distribution inside a small incinerator. A finite volume commercial code, PHONICS, is used to simulate the temperature field in an incinerator. The computational grid system is constructed by Multi-Block technique. The governing equations based on the curvilinear coordinates are used. Numerical experiments are done with the five variations of secondary air inlet. The temperature distribution is quantified by the statistical deviation of temperature in an incinerator. The computational analysis says that the certain angle of secondary air inlet could improve the uniformity of temperature distribution in an incinerator.

Abstract

1. 서론

2. 지배 방정식 및 경계 조건

3. 수치 해석 방법

4. 수치 해석 결과 및 고찰

5. 결론

참고문헌

(0)

(0)

로딩중