Detection of Early Visual Field Change in Ocular Hypertension Using STATPAC
- Hyun Joon Park Dong Myung Kim Dong Ho Youn Chul Hong
- 대한안과학회
- The Korean Journal of Ophthalmology
- Vol.4 No.1
- 등재여부 : KCI등재
- 1990.06
- 16 - 22 (7 pages)
Perimetric tests were performed on 32 ocular hypertensive eyes (17 patients) with the C-30-2 threshold program of the Humphery Visual Field Analyzer. The global indices of 32 ocular hypertensive eyes were compared with those of 34 normal eyes (17 controls). None of the 34 normal eyes had visual field sensitivity loss. However, three out of 32 ocular hypertensive eyes, which is 0.4%, had visual field sensitivity loss. Of these three eyes, two eyes showed generalized depression (MD, P < 5%) and one eye showed parncentral scotoma.
Abstract
INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
REFERENCES