직사각핀의 비오트수에 따른 냉각효과에 대한 해석

Analysis of Cooling Efficiency Using the Biot Number of a Rectangular Fin

DOI : 10.29279/kostet.2020.25.3.75
  • 25

The performance of a rectangular fin, the relative value of the performance for L=0.1, and the ratio of the heat transfer from the fin tip to the total heat transfer from the rectangular fin were investigated using a two-dimensional analytical method. The variables are the Biot number and non-dimensional fin length. The relative resistance, effect, and efficiency increase as the non-dimensional length increases for a small Biot number (Bi≤0.1). On the other hand, the relative resistance and effect decrease and the relative efficiency increases as the non-dimensional length increases for a large Biot number (Bi≥0.7).

Ⅰ. 서 론

Ⅱ. 이론적 해석

Ⅲ. 결과 및 고찰

Ⅳ. 결 론

참고문헌