수술 중 급격히 발생한 친수성 다초점 인공수정체 혼탁 1예
A Case of Rapidly Occurring Intraoperative Clouding of Hydrophilic Multifocal Intraocular Lens
- 대한검안학회
- Annals of optometry and contact lens
- Vol.14 No.3
- 2015.09
- 163 - 165 (3 pages)
Purpose: To report a case of intraoperative clouding of hydrophilic multifocal intraocular lens (Lentis Mplus?? LS-313, Oculentis GmbH., Berlin, Germany) during cataract surgery. Case summary: A 69-year-old woman underwent intraocular lens exchange in her left eye due to clouding of an intraocular lens occurred intraoperatively. This phenomenon was caused by the rapid change in temperature of a very cold IOL being implanted into the eye. Conclusions: It is important to prevent a rapid temperature change during intraocular lens implantation. Particularly in the country that have winter season and fluctuating temperatures, careful caution will be necessary.
증례보고
고 찰
REFERENCES