철 석출장치에 의한 폐수 중의 인 제거 특성

Characterization of Phosphorus Removal in Wastewater Using Iron Precipitation Reactor

  • 7

This study was conducted to improve an effect of phosphorus removal using FNR(Ferrous Nutrient Removal) process which had iron precipitation reactor and to analyze the iron corrosion. For simultaneous removal of phosphorus, iron electrolysis was combined with oxic tank. In this study, The removal efficiency of phosphorus increased with an increase voltage in iron precipitation reactor. The distance of 15 mm between the two iron bed in each tests influence the concentration of remaining phosphorus most. The extensive surface area of iron bed is the more removes the phosphorus. In this test the 400 cm2 of surface area was proved to be the most removal efficient.

Ⅰ. 서론

Ⅱ. 실험방법

Ⅲ. 결과 및 고찰

Ⅳ. 결론