This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from con-trast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were di-rectly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.