상세검색
최근 검색어 전체 삭제
다국어입력
즐겨찾기0
학술저널

¹⁸F-FDG PET/CT 검사에서 신장 방사능의 효과적인 배설 방법에 관한 연구

Evaluation of the Effective Methods for Renal Washout on ¹⁸F-FDG PET/CT

  • 2
커버이미지 없음

Purpose: Renal excretion is the main route of FDG clearance in FDG PET/CT scan. Applying optimal method of renal excretion is very important for enhancing image quality and diagnostic accuracy. We evaluated several methods of renal excretion in FDG PET/CT scan. Materials and Methods: Thirty patients with normal renal function were prospectively included. Patients were divided into three group and undergone early and delayed FDG PET/CT scans. (1) Delay group; at 1 hour later of early scan, delayed scan was performed without additional hydration, (2) Hydration group; at 1 hour later of early scan, delayed scan was performed with additional oral hydration (700 mL of water), (3) Lasix group; lasix was administered at the end of early scan and dealyed scan was performed 30 min later. Early and delayed scans were compared to evaluate efficiency of renal excretion. Visual and quantitative analyses were performed by experienced physician and technologist of nuclear medicine. Results: On the visual analysis, renal excretion was the most evident in Lasix group followed by Hydration group. Delay group showed poor renal excretion. On the quantitative analysis, washout rates were 9.2±20.7 %, 28.1±22.8 % and 29.5±23.1 % for Delay, Hydration and Lasix groups, respectively. Conclusion: Administration of lasix was the best method for enhancing renal excretion. Delayed scan with hydration was also efficient method, but delayed scan without hydration was not adequate method.

서론

실험재료 및 방법

결과

고찰

결론

요약

REFERENCES

(0)

(0)

로딩중