This study is aiming at researching and analyzing Reaction-to-fire's performance on Multi-layered sandwich panels which consist of cores with EPS and Glass wool. Three kinds of fire tests were made for the Multi-layered sandwich panel, EPS panel and Glass wool panel as well. Those three fire tests are ISO 5660-1(small scale test), EN 13823(medium scale test), and ISO 13784-1(large scale test). Furthermore Consideration for the reasonability of currently used fire retardant test on building material in Korea was deeply taken.
1. 서 론
2. 화재 시험 규모별 평가방법 및 개요
3. 화재시험 연소성능 결과분석
4. 결 론