국가지식-학술정보
Evaluation of Unavailability of the Containment Spray System by use of a Cause-Consequence Chart
Evaluation of Unavailability of the Containment Spray System by use of a Cause-Consequence Chart
- 한국원자력학회
- Nuclear Engineering and Technology
- Vol.11 No.3
-
1979.01195 - 202 (8 pages)
- 0
커버이미지 없음
In this paper, a cause-consequence chart is applied to evaluate the probability that the containment spray system in a nuclear power plant may not be woring properly, given a demand for spryaing at loss of coolant accident (LOCA). It is shown how the diagram provides a basis for calculating two probability measures for malfunctioning of this system, in case the test policy of the system is taken into account, i.e., average probability that the containment spray cannot be established, and average probability that the containment spray is established : spray stops before the required operating time is over.