개심술시 장시간 대동맥 차단 [200 분]: 3례 보고

Prolonged aortic cross clamping time of open heart surgery [200min.]

  • 0
커버이미지 없음

Three cases of multiple cardiac valve replacement were done in March 1983 at the department of thoracic and cardiovascular surgery, Chosun University College of Medicine. The patients were moderately symptomatic in all cases, and belonged to the class II and III of the NYHA functional criteria. The diseased valved were replaced with Bjork--Shiley, Ionescu-shiley valve prosthesis under cardiopulmonary bypass using hemodilution technique. The kind of cardioplegic solution used in our institute were Young and GIKs solution with core surface cooling. The average cardiopulmonary bypass time was 251.6 minutes and the average aortic cross clamping time was 223 minutes for aortic and mitral valve replacement. There was no operative morality.