변형 Blalock-Taussig수술후의 임상적 개선효과
Clinical Improvement after Modified Blalock-Taussig Shunt in Cyanotic Heart Disease
- 대한심장혈관흉부외과학회
- Journal of Chest Surgery
- Vol.28 No.11
-
1995.01983 - 988 (6 pages)
- 0
From January 1983 to December 1994, 48 cyanotic patients were underwent a subclavian artery-pulmonary artery shunt using polytetrafluoroethylene[PTFE for the purpose of improvement of reduced pulmonary blood flow. The diameters of the PTFE used were 4mm[4 cases , 5mm[36 cases , and 6mm[8 cases sizes. The effectiveness of modified Blalock-Taussig shunts was evaluated clinically and angiographically. There were 5 early deaths and 2 late deaths. There were 3 early shunt failures and 5 late shunt failures. The overall graft patency rate was 83.3%. Postoperative hemoglobin was reduced significantly[p = 0.0011 in comparison of the preoperative and postoperative hemoglobin, SaO2, PaO2, and cardiothoracic ratio.
(0)
(0)