공기 흡입이 소형 스크류식 원심펌프의 특성에 미치는 영향
Effects of Entrained Air on the Characteristics of a Small Screw-type Centrifugal Pump
- 한국유체기계학회
- The KSFM Journal of Fluid Machinery
- Vol.2 No.3 Serial No.4
-
1999.0137 - 44 (8 pages)
- 0
In a screw-type centrifugal pump, the pump head deteriorates from single-phase flow to the choke due to an increased air entrainment at a wide tip clearance compared to that of a narrow tip clearance. Moreover, at a narrow tip clearance, the pump head became partially higher in a two-phase flow than that of a single-phase flow near the best efficiency point in low void fraction region. Therefore, we observed the internal flow pattern by using a stroboscope and we measured the mean size of bubbles from the images obtained with a high speed camera. Then, we investigated the influences of the mean size of bubbles, tip clearances and flow patterns on pump performance.