역미셀을 이용한 Lysozyme 추출에 대한 물질 전달
Mass Transfer of Lysozyme Extraction Using Reversed Micelles
- 한국생물공학회
- KSBB Journal
- Vol.16 No.3
-
2001.01241 - 245 (5 pages)
- 0
Mass transfer rates have been measured for the extraction of enzyme from aqueous solution into a reverse-micelle phase at $25^{\circ}C$. The 420 mL vessel was carefully designed to maintain a planar interface between the aqueous and solvent phases, so allowing precise measurement of interfacial area, has been investigated. Sodium di-2-ethylhexyl sulfosuccinate(AOT) was the surfactant used. Factors varied included: agitator speed, pH, ionic strength and surfactant concentration. Samples were taken from the solvent phase at 15min intervals, and the amount of enzyme extracted was measured by UV absorption at 280 nm. The observed Sherwood numbers for the aqueous phase $Sh_1$were correlated interms of the aqueous phase Reynolds number $Re_1$, and modified Schmidt number $Sc_1$. $Sh_1=0.664Re_1^{0.5}Sc_1^{0.33}$
(0)
(0)