교류발전기 병렬운전시 과도현상 해석에 관한 연구
A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators
- 한국마린엔지니어링학회
- Journal of Advanced Marine Engineering and Technology
- Vol.25 No.5
-
2001.011065 - 1075 (11 pages)
- 0
It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.
(0)
(0)