A New Sustain Driving Method for AC PDP : Charge-Controlled Driving Method
A New Sustain Driving Method for AC PDP : Charge-Controlled Driving Method
- 대한전기학회
- KIEE International Transactions on Electrophysics and Applications
- Vol.2C No.6
-
2002.01292 - 296 (5 pages)
- 0
A new sustain driving method for the AC PDP is presented. In this driving method, the voltage source is connected to a storage capacitor, this storage capacitor charges an intermediate capacitor through LC resonance, and the panel is charged from the intermediate capacitor indirectly. In this way, the current flowing into the AC PDP when the sustain discharge occurs is reduced because the current is indirectly supplied from a capacitor, a limited source of charge. Thus, the input power to the output luminance efficiency is improved. Since the voltage supplied to the storage capacitor is doubled through LC resonance, this method call drive an AC PDP with a voltage source of about half of the voltage necessary in the conventional driving methods. The experiments showed that this charge-controlled driving method could drive ail AC PDP with a voltage source of as low as 107V. Using a panel of the conventional structure, luminous efficiency of 1.28 lm/W was achieved.
(0)
(0)