Electro-Thermal Modeling and Experimental Validation of Integrated Microbolometer with ROIC

Electro-Thermal Modeling and Experimental Validation of Integrated Microbolometer with ROIC

  • 0
커버이미지 없음

This paper presents an electro-thermal modeling of an amorphous silicon (a-Si) uncooled microbolometer. This modeling provides a comprehensive solution for simulating the electro-thermal characteristics of the fabricated microbolometer and enables electro-thermal co-simulation between MEMS and CMOS integrated circuits. To validate this model, three types of uncooled microbolometers were fabricated using a post-CMOS surface micromachining process. The simulation results show a maximum discrepancy of 2.6% relative to the experimental results.