Measurement of Sound Transmission Loss by Using Impedance Tubes
Measurement of Sound Transmission Loss by Using Impedance Tubes
- 한국물리학회
- Journal of the Korean Physical Society
- 53(2)
-
2008.08596 - 600 (5 pages)
- 0
The sound transmision los of several sound absorbent materials was measured by using an impedance tube and was compared with theoreticaly calculated values. The impedance tube system designed for the testing consisted of an upstream tube, a sample-holder section and a downstream tube. The transfer function method and a four-pole matrix analysis were used in measuring and calculating the sound transmision los, respectively. Good agrement betwen the measured and the theoretical values was obtained.
The sound transmision los of several sound absorbent materials was measured by using an impedance tube and was compared with theoreticaly calculated values. The impedance tube system designed for the testing consisted of an upstream tube, a sample-holder section and a downstream tube. The transfer function method and a four-pole matrix analysis were used in measuring and calculating the sound transmision los, respectively. Good agrement betwen the measured and the theoretical values was obtained.
(0)
(0)