시멘트 종류에 따른 티타늄 임프란트에 대한 주조체의 유지력
- 崔牧均 聚昶 崔丙哲 金光兹
- 대한치과이식임플란트학회
- Journal of Dental Implant Research
- 제9권 제1호
- 등재여부 : KCI등재후보
- 1989.12
- 32 - 37 (6 pages)
The purpose of this investigation was to test the retention of the castings to titanium implants in dental cements. After making copings with type IE gold, noble metal alloy for ceramics and base metal alloy for ceramics, we cemented them on the abutment of titanium implant with zinc phosphate cement, polycarboxylate cement and glass ionomer cement, and then tested the retention force on an Instron. The results of this study were as follows: 1. The zinc phosphate cement was distinctly superior to polycarboxylate cement and glass ionomer cement regardless of types of alloy in retentive force. 2. There was no statistically significant difference between polycarboxylate cement and glass ionomer cement. 3. Little difference was observed in the retentive forces of three types of alloy regardless of cements.
서 론
실험재료 및 방법
결 과
총괄 및 고찰
결 론
참 고 문 헌