상세검색
최근 검색어 전체 삭제
다국어입력
즐겨찾기0
커버이미지 없음
KCI등재 학술저널

The Application of ParalluxTM System for Multi-Detection of (Fluoro)quinolone Class Antibiotics Residues in Raw Bovine Milk

This study aimed to apply the Parallux system to detect (fluoro)quinone antibiotics residues in raw bovine milk. The immunogen enabled the generation of a specific antiserum with a titer of 1/40,000. The ParalluxTM kit using the antibody displayed IC50 value of 10 to 150 ppb for (fluoro)quinolone antibiotics. ParalluxTM kit was also sensitive for the detection of incurred (fluoro)quinolone at Korean Maximum Residual Levels in raw bovine milk as the result of dose response test. Cross reactivities of the antibody with the common (fluoro)quinolones were determined to be norfloxacin, 100%; enrofloxacin, 100%; ciprofloxacin, 100%; danofloxacin, 100%; nalidixic acid, 40%. Lower detection limit (LOD) values of the ParalluxTM kit in raw bovine milk were determined to be norfloxacin, 4 ppb; enrofloxacin, 5 ppb; danofloxacin, 5 ppb; ciprofloxacin, 5 ppb and nalidixic acid, 10 ppb. The ParalluxTM kit was run 8 times with five different concentrations of norfloxacin to determine the coefficient of variation (CV, %) of intra-assay, which was between 2.7% and 11.8%. To confirm the precision among kit batches for the inter-assay, five different batch kits were tested with 2 different concentration of norfloxacin. The CVs of the inter assay were 4.2% at 50 ppb, and 7.2% at 10 ppb norfloxacin, respectively.